Description
The stand must simulate the operating mode and measure the output characteristics of the removed electrical equipment in order to check its functionality, as well as determine the technical condition and troubleshoot.
Must ensure verification of: relay regulators; relay-breakers; electric drives of vehicle components; generators under load and at idle; starters in full braking and idle mode; starter traction relays; switching relays; resistors; semiconductor devices; armature windings. Test modes should be as close as possible to operating conditions, namely, the rotation speed and load current should be varied smoothly.
Module specifications:
Rotation speed, rpm, in the range of at least 0-10000
Direct current strength, A 0-5, 0-150, 0-50, 0-1000
DC and AC voltage, V 0-2, 0-20, 0-40
Torque, Nm, in the range of at least 0-100
DC resistance, Ohm, in the range of at least 0-100000
Max. power consumed from the network when checking starters, no more than, kW 22
Time to establish the operating mode, no more than, min no more than 15 minutes
Rated voltage of the electrical equipment being tested, V 12 / 24V
Overall dimensions, mm, no more (length x width x height) 1200x850x1600