Description
This laboratory is intended to organize a site for conducting or training competitors for the WorldSkills Russia (WSR) competition in the competency “Trunk communication lines. Construction and operation of fiber-optic transmission lines.» The laboratory contains a complex of laboratory equipment, hardware and methodological support.
Number of participants — 12
Workplace equipment
• Working table with additional lighting lamp 6
• Fiber recycling container 6
• Two-frame telecommunications rack 24/33U 6
• Gutter with fastening elements 6
• Tool set NIM-25 6
• Universal bracket for mounting MTok 6 couplings
• Mounting clamp for cables 12
• Key for mounting MTok 6 couplings
• Cross optical 19» 32 sockets 6
• Normalizing coil SM 1km 6
• Optical patch cord FC 42
• Bare optical fiber connection device 6
• Technical hair dryer 6
• Visible radiation source 6
• Reflectometer 6
• Welding machine 6
• Precision cleaver for optical fibers 6
Consumables:
• Kim-Wipes, lint-free (280 pcs. per pack) 6
• 2-Propanol 1l. 6
• D-gel (liquid for removing hydrophobic gel) 1 l 6
• Marker for modules 0.9 6
• Permanent marker (indelible), black 6
• Permanent marker (indelible), red 6
• Universal insulating tape, blue 19mm x 20m x 0.13mm 6
• Universal insulating tape, yellow 15mm x 10m x 0.13mm 6
• Plastic marking kit KMP (package contains 50 sets and 1 marker) 6
• Heat-shrinkable sleeve SSD KDZS-4525 (10 pcs per package) 400
• Optical coupling MTOC 6
• Set No. 4 for OK input (MTOK-B1, V2, V3, K6, M6, BB) 12
• Optical cable 8 fibers with wire armor 600m
• Kit for connecting armored cover OK with wire armor 12
• Clamps (ties), nylon, 3 mm x 150 mm, set 100 pcs 6
• Clamps (ties), nylon, 5 mm x 300 mm, set 100 pcs 6
• Clamps (ties), nylon, 2.5 mm x 100 mm, set of 100 pcs 6
• Kit for installing an optical cross-connect in a 24 rack
• Set of wrenches 6- 21 6
Personal protective equipment
• Safety glasses 12
• Gloves xb 36
• Rubber gloves 36
• Rubberized apron 12
Methodological recommendations for completing tasks:
• Installation of station equipment, according to documentation
• Incoming cable control
• Installation of optical CROSS (install an optical cable, install an optical CROSS)
• Installation of optical couplings
• Measurements of installed line parameters
• Locating damage using an optical reflectometer
• Preparation of acts and passports.