Description
• Reading fault memory, displaying current values, activating actuators, using other specific functions of control devices
• 2-channel oscilloscope for recording measured values
• 2-channel diagnostic oscilloscope for analyzing the diagnostic interface of control units
• Smart and future-proof thanks to internal OBD variable adapter
• Easy connection to the car
• Universal use for passenger cars and commercial vehicles using the universal OBD connector, for 14 V and 28 V on-board networks
• Clear communication thanks to multiplexer and cable adapter recognition: possibility of switching wires K and L, SAE and CAN to all possible terminals of the OBD connector
• Reliable multiplexer activation
• Automatic search function for control units
• Visual and acoustic status recognition / radio communication monitoring
• Possibility to customize the simulation mode using DDC, demonstration without a car is possible
• Resistance measurement with extended measuring ranges
• Continuity indicator for fault location
• Diode measurement for testing in components
• Voltage measurement with advanced measurement functions
• Bluetooth class 1 standard with range up to 100 m
• Automatic search for KTS modules
• Based on ESI[tronic] 2.0
Technical data:
Operating voltage 8 – 28 V DC
Power consumption from car battery or power supply 10 Watt
Dimensions with black protective rubber corners (W x H x D) 130 x 45 x 185 mm
Weight (without connecting wires) 0.5 kg
Type of protection (with the protective cover closed and the OBD connecting cable connected) IP 53
Operating temperature СС – 405
Storage temperature СС – 60-25
Relative humidity of operating air (non-condensing) 20% — 80%
Voltage measurement:
Measuring range 200 mV – 60 V DC / 30 V AC
Accuracy ±0.75% of measured value,
Plus ±0.25% of measuring range
AC Frequency Range 10 Hz – 100 kHz (-3 dB)
Resistance measurement:
Measuring range 100 Ohm – 1 Mohm
Accuracy 0.1 Ohm – 1000 Ohm
Input impedance >900 kOhm
Oscilloscope:
Measuring range 200 mV – 60 V DC / 30 V AC at peak value 42 V AC
Connection DC, AC, DC (+), DC (-)
Signal source CH1/CH2: U, 100 A, 600 A; Diagnostic connector pins 1 to 15 (except 4 and 5)
X-axis sweep 25 µs – 1 s
Signal matching Manually, with automatic adjustment by time or level
Frequency range Up to 5 MHz
Measurement rate 20 MI/s (MI = millions of measurements)